Product image | Description | Volume Range | Variant | Pack Type | Cat code |
---|---|---|---|---|---|
![]() |
AHN myTip® 10 µL, clear, bag | 10 μL | Standard tips | Bag case | 1-002-81-0 |
![]() |
AHN myTip® FT 20 µL, clear, bag | 20 μL | Filter tips | Bag case | 2-117-80-0 |
![]() |
AHN myTip® 10 µL, clear, racked | 10 μL | Standard tips | Racked case | 1-002-C5-0 |
![]() |
AHN myTip® 10 µL, clear, sterile, racked | 10 μL | Standard tips | Racked case | 1-003-C5-0 |
![]() |
AHN myTip® 10/20 µL XL, clear, bag | 10/20 μL XL | Standard tips | Bag case | 1-062-81-0 |
![]() |
AHN myTip® 10/20 µL XL, clear, racked | 10/20 μL XL | Standard tips | Racked case | 1-062-C5-0 |
![]() |
AHN myTip® 10/20 µL XL, clear, sterile, racked | 10/20 μL XL | Standard tips | Racked case | 1-063-C5-0 |
![]() |
AHN myTip® FT 100 µL, clear, bag | 100 μL | Filter tips | Bag case | 2-119-80-0 |
![]() |
AHN myTip® 200 µL, clear, bag | 200 μL | Standard tips | Bag case | 1-121-86-0 |
![]() |
AHN myTip® 200 µL, clear, racked | 200 μL | Standard tips | Racked case | 1-121-C5-0 |
![]() |
AHN myTip® 200 µL, clear, sterile, racked | 200 μL | Standard tips | Racked case | 1-122-C5-0 |
![]() |
AHN myTip® 200 µL, yellow, bag | 200 μL | Standard tips | Bag case | 1-121-86-1 |
![]() |
AHN myTip® 200 µL, yellow, racked | 200 μL | Standard tips | Racked case | 1-121-C5-1 |
![]() |
AHN myTip® 200 µL, yellow, sterile, racked | 200 μL | Standard tips | Racked case | 1-122-C5-1 |
![]() |
AHN myTip® 200 µL Gelloader, clear, racked | 200 μL | Standard tips | Racked case | 1-130-C4-0 |
![]() |
AHN myTip® 200 µL Gelloader, racked, sterile | 200 μL | Standard tips | Racked case | 1-131-C4-0 |
![]() |
AHN myTip® 300 µL, clear, bag | 300 μL | Standard tips | Bag case | 1-127-80-0 |
![]() |
AHN myTip® 300 µL, clear, racked | 300 μL | Standard tips | Racked case | 1-127-C5-0 |
![]() |
AHN myTip® 300 µL, clear, sterile, racked | 300 μL | Standard tips | Racked case | 1-128-C5-0 |
![]() |
AHN myTip® 1000 µL, clear, bag | 1000 μL | Standard tips | Bag case | 1-202-80-0 |
![]() |
AHN myTip® 1000 µL, clear, racked | 1000 μL | Standard tips | Racked case | 1-202-C4-0 |
![]() |
AHN myTip® 1000 µL, clear, sterile, racked | 1000 μL | Standard tips | Racked case | 1-203-C4-0 |
![]() |
AHN myTip® 1000 µL, blue, bag | 1000 μL | Standard tips | Bag case | 1-202-80-2 |
![]() |
AHN myTip® 1000 µL, blue, racked | 1000 μL | Standard tips | Racked case | 1-202-C4-2 |
![]() |
AHN myTip® 1000 µL, blue, sterile, racked | 1000 μL | Standard tips | Racked case | 1-203-C4-2 |
![]() |
AHN myTip® 1250 µL, clear, bag | 1250 μL | Standard tips | Bag case | 1-204-80-0 |
![]() |
AHN myTip® 1250 µL, clear, racked | 1250 μL | Standard tips | Racked case | 1-204-C4-0 |
![]() |
AHN myTip® 1250 µL, clear, sterile, racked | 1250 μL | Standard tips | Racked case | 1-205-C4-0 |
![]() |
AHN myTip® MaT 5 mL, clear, bag | 5 mL | Standard tips | Bag case | 1-218-61-0 |
![]() |
AHN myTip® MaT 5 mL, clear, sterile, bag | 5 mL | Standard tips | Bag case | 1-222-61-0 |
![]() |
AHN myTip® MaT 1-5 ml, clear, bag | 5 mL | Standard tips | Bag case | 1-210-84-0 |
![]() |
AHN myTip® MaT 5.5 ml, clear, bag | 5.5 mL | Standard tips | Bag case | 1-212-84-0 |
![]() |
AHN myTip® MaT 1-10 ml, clear, bag | 10 mL | Standard tips | Bag case | 1-213-50-0 |
![]() |
AHN myTip® MaT 10 mL, clear, bag | 10 mL | Standard tips | Bag case | 1-220-50-0 |
![]() |
AHN myTip® MaT 10 mL, clear, sterile, bag | 10 mL | Standard tips | Bag case | 1-224-50-0 |
![]() |
AHN myTip® FT 10 µL, clear, bag | 10 μL | Filter tips | Bag case | 2-002-81-0 |
![]() |
AHN myTip® FT 10 µL, clear, sterile, racked | 10 μL | Filter tips | Racked case | 2-003-C5-0 |
![]() |
AHN myTip® FT 10 µL XL w/ lower filter, clear, bag | 10 μL XL | Filter tips | Bag case | 2-061-81-0 |
![]() |
AHN myTip® FT 10 µL XL w/ lower filter, clear, sterile, racked | 10 μL XL | Filter tips | Racked case | 2-064-C5-0 |
![]() |
AHN myTip® FT 20 µL XL, clear, bag | 20 μL XL | Filter tips | Bag case | 2-062-81-0 |
![]() |
AHN myTip® FT 20 µL XL, clear, sterile, racked | 20 μL XL | Filter tips | Racked case | 2-063-C5-0 |
![]() |
AHN myTip® FT 20 µL, clear, sterile, racked | 20 μL | Filter tips | Racked case | 2-118-C5-0 |
![]() |
AHN myTip® FT 100 µL, clear, sterile, racked | 100 μL | Filter tips | Racked case | 2-120-C5-0 |
![]() |
AHN myTip® FT 200 µL, clear, bag | 200 μL | Filter tips | Bag case | 2-127-80-0 |
![]() |
AHN myTip® FT 200 µL, clear, sterile, racked | 200 μL | Filter tips | Racked case | 2-128-C5-0 |
![]() |
AHN myTip® FT 300 µL, clear, bag | 300 μL | Filter tips | Bag case | 2-134-80-0 |
![]() |
AHN myTip® FT 300 µL, clear, sterile, racked | 300 μL | Filter tips | Racked case | 2-135-C5-0 |
![]() |
AHN myTip® FT 1000 µL, clear, bag | 1000 μL | Filter tips | Bag case | 2-202-80-0 |
![]() |
AHN myTip® FT 1000 µL, clear, sterile, racked | 1000 μL | Filter tips | Racked case | 2-203-C4-0 |
![]() |
AHN myTip® FT 1250 µL, clear, bag | 1250 μL | Filter tips | Bag case | 2-204-80-0 |
![]() |
AHN myTip® FT 1250 µL, clear, sterile, racked | 1250 μL | Filter tips | Racked case | 2-205-C4-0 |
![]() |
AHN myTip® LT 10 µL, clear, bag | 10 μL | Low Retention tips | Bag case | 4-002-81-0 |
![]() |
AHN myTip® LT 10 µL, clear, sterile, racked | 10 μL | Low Retention tips | Racked case | 4-003-C5-0 |
![]() |
AHN myTip® LT 10/20 µL XL, clear, bag | 10/20 μL XL | Low Retention tips | Bag case | 4-062-81-0 |
![]() |
AHN myTip® LT 10/20 µL XL, clear, sterile, racked | 10/20 μL XL | Low Retention tips | Racked case | 4-063-C5-0 |
![]() |
AHN myTip® LT 200 µL, clear, bag | 200 μL | Low Retention tips | Bag case | 4-121-86-0 |
![]() |
AHN myTip® LT 200 µL, clear, sterile, racked | 200 μL | Low Retention tips | Racked case | 4-122-C5-0 |
![]() |
AHN myTip® LT 300 µL, clear, bag | 300 μL | Low Retention tips | Bag case | 4-127-80-0 |
![]() |
AHN myTip® LT 300 µL, clear, sterile, racked | 300 μL | Low Retention tips | Racked case | 4-128-C5-0 |
![]() |
AHN myTip® LT 1000 µL, clear, bag | 1000 μL | Low Retention tips | Bag case | 4-202-80-0 |
![]() |
AHN myTip® LT 1000 µL , clear, sterile | 1000 μL | Low Retention tips | Racked case | 4-203-C4-0 |
![]() |
AHN myTip® LT 1250 µL, clear, bag | 1250 μL | Low Retention tips | Bag case | 4-204-80-0 |
![]() |
AHN myTip® LT 1250 µL, clear, sterile, racked | 1250 μL | Low Retention tips | Racked case | 4-205-C4-0 |
![]() |
AHN myTip® LFT 10 µL, clear, sterile, racked | 10 μL | low retention filter tips | Racked case | 5-003-C5-0 |
![]() |
AHN myTip® LFT 10 µL XL w/ lower filter, clear, Low Retention, sterile, racked | 10 μL XL | low retention filter tips | Racked case | 5-064-C5-0 |
![]() |
AHN myTip® LFT 20 µL XL, clear, sterile, racked | 20 μL XL | low retention filter tips | Racked case | 5-063-C5-0 |
![]() |
AHN myTip® LFT 20 µL, clear, sterile, racked | 20 μL | low retention filter tips | Racked case | 5-118-C5-0 |
![]() |
AHN myTip® LFT 100 µL, clear, sterile, racked | 100 μL | low retention filter tips | Racked case | 5-120-C5-0 |
![]() |
AHN myTip® LFT 200 µL, clear, sterile, racked | 200 μL | low retention filter tips | Racked case | 5-128-C5-0 |
![]() |
AHN myTip® LFT 300 µL, clear, sterile, racked | 300 μL | low retention filter tips | Racked case | 5-135-C5-0 |
![]() |
AHN myTip® LFT 1000 µL, clear, sterile, racked | 1000 μL | low retention filter tips | Racked case | 5-203-C4-0 |
![]() |
AHN myTip® LFT 1250 µL, clear, sterile, racked | 1250 μL | low retention filter tips | Racked case | 5-205-C4-0 |
![]() |
AHN myTip® RL 10 µL, clear, reload | 10 μL | Standard tips | Reload case | 1-002-C1-R |
![]() |
AHN myTip® RL 10/20 µL XL, clear, reload | 10/20 μL XL | Standard tips | Reload case | 1-062-C1-R |
![]() |
AHN myTip® RL 200 µL, clear, reload | 200 μL | Standard tips | Reload case | 1-121-C1-R |
![]() |
AHN myTip® RL 300 µL, clear, reload | 300 μL | Standard tips | Reload case | 1-127-C2-R |
![]() |
AHN myTip® RL 1000 µL, clear, reload | 1000 μL | Standard tips | Reload case | 1-202-C3-R |
![]() |
AHN myTip® RL 1250 µL, clear, reload | 1250 μL | Standard tips | Reload case | 1-205-C3-R |
![]() |
AHN myTip® RL 10 µL, Low Retention, clear, reload | 10 μL | Low Retention tips | Reload case | 4-002-C1-R |
![]() |
AHN myTip® RL 10/20 µL XL, Low Retention, clear, reload | 10/20 μL XL | Low Retention tips | Reload case | 4-062-C1-R |
![]() |
AHN myTip® RL 200 µL, Low Retention, clear, reload | 200 μL | Low Retention tips | Reload case | 4-121-C1-R |
![]() |
AHN myTip® RL 300 µL, Low Retention, clear, reload | 300 μL | Low Retention tips | Reload case | 4-127-C2-R |
![]() |
AHN myTip® RL 1000 µL, Low Retention, clear, reload | 1000 μL | Low Retention tips | Reload case | 4-202-C3-R |
![]() |
AHN myTip® RL 1250 µL, Low Retention, clear, reload | 1250 μL | Low Retention tips | Reload case | 4-205-C3-R |
![]() |
AHN myTip® RB empty for 10 µL/10 µL XL tips, 8x12 | - | clear black (RB) / light grey (I) | case/5x10 | 4-500-C5-E |
![]() |
AHN myTip® RB empty for 200 µL/300 µL tips, 8x12 | - | clear black (RB) / yellow (I) | case/5x10 | 4-501-C5-E |
![]() |
AHN myTip® RB empty for 200 µL GL tips, 8x12 | - | clear black (RB) / yellow (I) | case/4x8 | 4-502-C4-E |
![]() |
AHN myTip® RB empty for 1000 µL tips, 8x12 | - | clear black (RB) / blue(I) | case/4x8 | 4-503-C4-E |
![]() |
AHN myTip® RB empty for 1250 µL tips, 8 x 12 | - | clear black (RB) / blue(I) | case/4x8 | 4-504-C4-E |
Material Quality used for AHN Pipette Tips
AHN Pipette Tips are manufactured from non-cytotoxic, biologically inert and highly transparent, medical-grade virgin polypropylene. They are free from bioactive additives, softening agents such as biocides, slip and antistatic agents. AHN Pipette Tips are universally compatible with the majority of commonly used pipette brands.
Ultimate finish of AHN Tips
Manufactured in a top modern, automated production facility located in Central Germany and utilizing state-of-the-art Swiss-made diamond finish molds, AHN Pipette Tips offer a flawless and extra smooth internal surface and an ultimate finish. AHN pipette Tips are manufactured in a clean room, world-class, fully automated, human-touch-free production facility under a strictly controlled environment.
Innovative design of AHN Pipette Tips
Thanks to improved cone geometry, AHN myTip® Micropipette Tips ensure universal fit on all commonly used pipette brands, as well as easy and effortless ejection. See the full compatibility list of AHN Pipette Tips. AHN myTip® Micropipette Tips are also equipped with graduation marks, enabling quick and convenient visual volume check, minimizing the error risk during aspiration. The unique design of AHN myTip® Pipette Tips allows for easy loading and ejection with the very minimum force requirement, preventing from repetitive strain injuries.
Pipette tips & Macro tips
Filter tips
Low retention tips